Power on alarm "brake Err"(T90) Sep 15, 2022

1. CHECK IF THE ELECTROMAGNETIC BRAKE IS TURNED ON. IF IT IS UPTURNED, PLEASE PULL THE ELECTROMAGNETIC BRAKE WRENCH DOWN.

2. CHECK IF THE ELECTROMAGNETIC BRAKE POWER CABLE IS OPEN CIRCUIT BY MULTIMETER. IF THE CIRCUIT IS DISCONNECTED, RECONNECT THE ELECTROMAGNETIC BRAKE POWER CABLE.

3. CHECK IF THE MACHINE'S BOOTING PROCEDURE IS CORRECT. SELECT THE RIGHT PROGRAM FOR THE MODEL. IF THE PROGRAM IS WRONG DUE TO INCORRECT OPERATION, PLEASE CONTACT YOUR LOCAL DISTRIBUTOR OR THE MANUFACTURER DIRECTLY.